Configure a UDP data input in Health Log Analytics manually
Set up a data input for sending raw log messages to your ServiceNow instance directly over a UDP socket.
Before you begin
This feature is supported in the Health Log Analytics application, Version 25.0.17 - November 2022 and later, available from the ServiceNow Store.
-
Verify that a MID Server is installed and configured with the Log Ingestion capability enabled. For more information, see MID Server system requirements.
[Omitted image "hla-mid-log-ingestion.png"] Alt text: MID Server configuration with Log Ingestion capability enabled.
Important: Health Log Analytics does not support IPv6. To work with the application, configure the MID Server to IPv4.
-
Unless the MID Server and external clients are on the same network, verify that the MID Server has a public IP address. This is required when its IP is exposed through network address translation (NAT), a load balancer, or a similar device. The public IP address enables external clients, such as Filebeat agents located outside its network, to reach the MID Server. Private IP addresses aren't routable over the internet. Without a public IP, external clients can't connect to the MID Server even if they are configured with its address. In the MID Server properties, add a property named mid.public_ip with the public IP address as the value. For more information, see Create a MID Server property. If the MID Server and external clients are on the same network, connections can be made using the private IP address.
-
For shipping your logs encrypted using SSL TLS, see the Streaming Data With Rsyslog & Filebeat Using SSL [KB0866319] article in the Now Support Knowledge Base.
Role required: evt_mgmt_admin
Procedure
-
Navigate to All > Health Log Analytics > Data Input > Data Inputs.
-
On the Data Inputs page, select New.
-
Choose the UDP data input type.
Note: The selected data input type complements the passive data input (listener). For more information, see Supported data inputs for Health Log Analytics.
-
On the form, fill in the fields.
For a description of the fields, see UDP data input configuration fields.
-
Select Advanced to set additional configuration fields.
For a description of the fields, see UDP data input configuration fields.
-
Select Save.
Health Log Analytics adds the data input record to the Data Inputs table.
-
Verify that the data input is configured correctly by selecting Test connection.
Health Log Analytics tries to connect the MID Server to the data repository.
-
If the connection was established, the Test connection button is turned off and the Publish button is enabled.
-
If the connection failed, the reason for the failure displays in the Error message field. Resolve the issue, select Save if you modified the configuration, and then select Test connection to test the connection again.
Note: You can only publish the data input configuration when the connection is created successfully.
Note: You can revert to the last published configuration by selecting Revert Changes. This option is available only when you're modifying a configuration that has been published previously.
-
-
Select Publish to publish the data input to the MID Server.
Result
The data input configuration process is complete. Health Log Analytics adds the data input record to the Data Inputs table and attaches the configuration file to the data input record. The data input starts sending raw log messages to your ServiceNow instance directly over a UDP socket.
Note: If the HLA engine is down and data has stopped streaming, a notification appears at the top of the data input configuration page. When this happens, contact ServiceNow support.
What to do next
Verify that the data input is streaming data.
Parent Topic:Configuring data inputs for Health Log Analytics manually
Related topics
Configure advanced settings for Rsyslog, Splunk, TCP data inputs
---
title: Configure a UDP data input in Health Log Analytics manually
description: Set up a data input for sending raw log messages to your ServiceNow instance directly over a UDP socket.
locale: en-US
canonical_url: https://www.servicenow.com/docs/r/australia/it-operations-management/health-log-analytics/hla-data-input-udp.html
release: australia
product: Health Log Analytics
classification: health-log-analytics
topic_type: task
last_updated: "2026-09-10"
reading_time_minutes: 3
keywords: [ServiceNow, Health Log Analytics, HLA, data input, configuration]
breadcrumb: [Manual data input configuration, Set up data inputs manually, Set up HLA on your instance, Configuring, Health Log Analytics, ITOM AIOps, IT Operations Management]
---
# Configure a UDP data input in Health Log Analytics manually
Set up a data input for sending raw log messages to your ServiceNow instance directly over a UDP socket.
## Before you begin
This feature is supported in the Health Log Analytics application, Version 25.0.17 - November 2022 and later, available from the [ServiceNow Store](https://store.servicenow.com/sn_appstore_store.do#!/store/home).
- Verify that a MID Server is installed and configured with the Log Ingestion capability enabled. For more information, see [MID Server system requirements](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/servicenow-platform/r_MIDServerSystemRequirements.md).
\[Omitted image "hla-mid-log-ingestion.png"\] Alt text: MID Server configuration with Log Ingestion capability enabled.
**Important:** Health Log Analytics does not support IPv6. To work with the application, configure the MID Server to IPv4.
- Unless the MID Server and external clients are on the same network, verify that the MID Server has a public IP address. This is required when its IP is exposed through network address translation \(NAT\), a load balancer, or a similar device. The public IP address enables external clients, such as Filebeat agents located outside its network, to reach the MID Server. Private IP addresses aren't routable over the internet. Without a public IP, external clients can't connect to the MID Server even if they are configured with its address. In the MID Server properties, add a property named **mid.public\_ip** with the public IP address as the value. For more information, see [Create a MID Server property](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/servicenow-platform/r_MIDServerProperties.md). If the MID Server and external clients are on the same network, connections can be made using the private IP address.
- For shipping your logs encrypted using SSL TLS, see the [Streaming Data With Rsyslog & Filebeat Using SSL \[KB0866319\]](https://support.servicenow.com/kb?id=kb_article_view&sysparm_article=KB0866319) article in the Now Support Knowledge Base.
Role required: evt\_mgmt\_admin
## Procedure
1. Navigate to **All** > **Health Log Analytics** > **Data Input** > **Data Inputs**.
2. On the Data Inputs page, select **New**.
3. Choose the UDP data input type.
**Note:** The selected data input type complements the passive data input \(listener\). For more information, see [Supported data inputs for Health Log Analytics](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/it-operations-management/health-log-analytics/hla-data-input-supported.md).
4. On the form, fill in the fields.
For a description of the fields, see [UDP data input configuration fields](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/it-operations-management/health-log-analytics/hla-data-input-udp-ref.md).
5. Select **Advanced** to set additional configuration fields.
For a description of the fields, see [UDP data input configuration fields](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/it-operations-management/health-log-analytics/hla-data-input-udp-ref.md).
6. Select **Save**.
Health Log Analytics adds the data input record to the Data Inputs table.
7. Verify that the data input is configured correctly by selecting **Test connection**.
Health Log Analytics tries to connect the MID Server to the data repository.
- If the connection was established, the **Test connection** button is turned off and the **Publish** button is enabled.
- If the connection failed, the reason for the failure displays in the **Error message** field. Resolve the issue, select **Save** if you modified the configuration, and then select **Test connection** to test the connection again.
**Note:** You can only publish the data input configuration when the connection is created successfully.
**Note:** You can revert to the last published configuration by selecting **Revert Changes**. This option is available only when you're modifying a configuration that has been published previously.
8. Select **Publish** to publish the data input to the MID Server.
## Result
The data input configuration process is complete. Health Log Analytics adds the data input record to the **Data Inputs** table and attaches the configuration file to the data input record. The data input starts sending raw log messages to your ServiceNow instance directly over a UDP socket.
**Note:** If the HLA engine is down and data has stopped streaming, a notification appears at the top of the data input configuration page. When this happens, contact ServiceNow support.
## What to do next
[Verify that the data input is streaming data.](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/it-operations-management/health-log-analytics/hla-data-input-streaming.md)
**Parent Topic:**[Configuring data inputs for Health Log Analytics manually](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/it-operations-management/health-log-analytics/hla-data-inputs-configuring.md)
**Related topics**
[Configure advanced settings for Rsyslog, Splunk, TCP data inputs](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/it-operations-management/health-log-analytics/hla-data-input-adv-rsyslog-splunk.md)
| title | Configure a UDP data input in Health Log Analytics manually |
| description | Set up a data input for sending raw log messages to your ServiceNow instance directly over a UDP socket. |
| locale | en-US |
| canonical_url | https://www.servicenow.com/docs/r/australia/it-operations-management/health-log-analytics/hla-data-input-udp.html |
| release | australia |
| product | Health Log Analytics |
| classification | health-log-analytics |
| topic_type | task |
| last_updated | 2026-09-10 |
| reading_time_minutes | 3 |
| keywords | ServiceNowHealth Log AnalyticsHLAdata inputconfiguration |
| breadcrumb | Manual data input configurationSet up data inputs manuallySet up HLA on your instanceConfiguringHealth Log AnalyticsITOM AIOpsIT Operations Management |