Uninterruptible power supply \(UPS\) discovery
reference australia Updated Sep 10, 2026 2 min read r_DataCollDiscoUnintPowerSupp.md
Discovery identifies and classifies information about an uninterruptible power supply (UPS).
Discovery can identify and classify uninterruptible power supplies.
| Label | Table name | Field name | Source |
|---|---|---|---|
| Serial number | cmdb_ci | serial_number | SNMP, various MIBs |
| Start date | cmdb_ci | start_date | SNMP, RFC1213 MIB |
| Manufacturer | cmdb_ci | manufacturer | SNMP, RFC1213 MIB |
| Model ID | cmdb_ci | model_id | SNMP, RFC1213 MIB |
| IP address | cmdb_ci_network_adapter | ip_address | SNMP, IP MIB |
| MAC address | cmdb_ci_network_adapter | mac_address | SNMP, IF MIB |
| UPS software version | cmdb_ci_ups | ups_software_version | SNMP, UPS MIB |
| Agent software version | cmdb_ci_ups | agent_software_version | SNMP, UPS MIB |
| Attached devices | cmdb_ci_ups | attached_devices | SNMP, UPS MIB |
| Battery status | cmdb_ci_ups | battery_status | SNMP, UPS MIB |
| Seconds remaining on battery | cmdb_ci_ups | seconds_on_battery | SNMP, UPS MIB |
| Estimated minutes remaining on battery | cmdb_ci_ups | est_mins_remaining | SNMP, UPS MIB |
| Estimated charge % remaining | cmdb_ci_ups | est_charge_remaining | SNMP, UPS MIB |
| Battery voltage | cmdb_ci_ups | battery_voltage | SNMP, UPS MIB |
| Battery current | cmdb_ci_ups | battery_current | SNMP, UPS MIB |
| Battery temperature (C) | cmdb_ci_ups | battery_temperature | SNMP, UPS MIB |
| Input line bads | cmdb_ci_ups | input_line_bads | SNMP, UPS MIB |
| Output source | cmdb_ci_ups | output_source | SNMP, UPS MIB |
| Output frequency | cmdb_ci_ups | output_freq | SNMP, UPS MIB |
| Bypass frequency | cmdb_ci_ups | bypass_freq | SNMP, UPS MIB |
| Nominal input voltage | cmdb_ci_ups | nom_input_volt | SNMP, UPS MIB |
| Nominal input frequency | cmdb_ci_ups | nom_input_freq | SNMP, UPS MIB |
| Nominal output voltage | cmdb_ci_ups | nom_output_volt | SNMP, UPS MIB |
| Nominal output frequency | cmdb_ci_ups | nom_output_freq | SNMP, UPS MIB |
| Rated output VA | cmdb_ci_ups | rated_output_va | SNMP, UPS MIB |
| Rated output power | cmdb_ci_ups | rated_output_power | SNMP, UPS MIB |
| Low battery threshold minutes | cmdb_ci_ups | low_battery_threshold_mins | SNMP, UPS MIB |
| Audible alarm status | cmdb_ci_ups | audible_alarm_status | SNMP, UPS MIB |
| Low voltage transfer point | cmdb_ci_ups | low_voltage_transfer_point | SNMP, UPS MIB |
| High voltage transfer point | cmdb_ci_ups | high_voltage_transfer_point | SNMP, UPS MIB |
| Input index | cmdb_ci_ups_input | input_index | SNMP, UPS MIB |
| Input frequency (Hz) | cmdb_ci_ups_input | input_freq | SNMP, UPS MIB |
| Input voltage (RMS VAC) | cmdb_ci_ups_input | input_volt | SNMP, UPS MIB |
| Input current (RMS AAC) | cmdb_ci_ups_input | input_current | SNMP, UPS MIB |
| Input power (Watts) | cmdb_ci_ups_input | input_power | SNMP, UPS MIB |
| Output index | cmdb_ci_ups_output | output_index | SNMP, UPS MIB |
| Output load (%) | cmdb_ci_ups_output | output_load | SNMP, UPS MIB |
| Output voltage (RMS VAC) | cmdb_ci_ups_output | output_volt | SNMP, UPS MIB |
| Output current (RMS AAC) | cmdb_ci_ups_output | output_current | SNMP, UPS MIB |
| Output power (Watts) | cmdb_ci_ups_output | output_power | SNMP, UPS MIB |
| Bypass index | cmdb_ci_ups_bypass | bypass_index | SNMP, UPS MIB |
| Bypass voltage (RMS VAC) | cmdb_ci_ups_bypass | bypass_volt | SNMP, UPS MIB |
| Bypass current (RMS AAC) | cmdb_ci_ups_bypass | bypass_current | SNMP, UPS MIB |
| Bypass power (Watts) | cmdb_ci_ups_bypass | bypass_power | SNMP, UPS MIB |
| Alarm index | cmdb_ci_ups_alarm | alarm_index | SNMP, UPS MIB |
| Alarm type | cmdb_ci_ups_alarm | alarm_type | SNMP, UPS MIB |
| Alarm time | cmdb_ci_ups_alarm | alarm_time | SNMP, UPS MIB |
Parent Topic:Network device discovery
73 lines · 4.3 KB
--- title: Uninterruptible power supply \(UPS\) discovery description: Discovery identifies and classifies information about an uninterruptible power supply \(UPS\). locale: en-US canonical_url: https://www.servicenow.com/docs/r/australia/it-operations-management/itom-visibility/r\_DataCollDiscoUnintPowerSupp.html release: australia product: ITOM Visibility classification: itom-visibility topic_type: reference last_updated: "2026-09-10" reading_time_minutes: 2 breadcrumb: [Network device discovery, Data collected by ITOM Visibility, ITOM Visibility reference, ITOM Visibility, IT Operations Management] --- # Uninterruptible power supply \(UPS\) discovery Discovery identifies and classifies information about an uninterruptible power supply \(UPS\). Discovery can identify and classify uninterruptible power supplies. |Label|Table name|Field name|Source| |-----|----------|----------|------| |Serial number|cmdb\_ci|serial\_number|SNMP, various MIBs| |Start date|cmdb\_ci|start\_date|SNMP, RFC1213 MIB| |Manufacturer|cmdb\_ci|manufacturer|SNMP, RFC1213 MIB| |Model ID|cmdb\_ci|model\_id|SNMP, RFC1213 MIB| |IP address|cmdb\_ci\_network\_adapter|ip\_address|SNMP, IP MIB| |MAC address|cmdb\_ci\_network\_adapter|mac\_address|SNMP, IF MIB| |UPS software version|cmdb\_ci\_ups|ups\_software\_version|SNMP, UPS MIB| |Agent software version|cmdb\_ci\_ups|agent\_software\_version|SNMP, UPS MIB| |Attached devices|cmdb\_ci\_ups|attached\_devices|SNMP, UPS MIB| |Battery status|cmdb\_ci\_ups|battery\_status|SNMP, UPS MIB| |Seconds remaining on battery|cmdb\_ci\_ups|seconds\_on\_battery|SNMP, UPS MIB| |Estimated minutes remaining on battery|cmdb\_ci\_ups|est\_mins\_remaining|SNMP, UPS MIB| |Estimated charge % remaining|cmdb\_ci\_ups|est\_charge\_remaining|SNMP, UPS MIB| |Battery voltage|cmdb\_ci\_ups|battery\_voltage|SNMP, UPS MIB| |Battery current|cmdb\_ci\_ups|battery\_current|SNMP, UPS MIB| |Battery temperature \(C\)|cmdb\_ci\_ups|battery\_temperature|SNMP, UPS MIB| |Input line bads|cmdb\_ci\_ups|input\_line\_bads|SNMP, UPS MIB| |Output source|cmdb\_ci\_ups|output\_source|SNMP, UPS MIB| |Output frequency|cmdb\_ci\_ups|output\_freq|SNMP, UPS MIB| |Bypass frequency|cmdb\_ci\_ups|bypass\_freq|SNMP, UPS MIB| |Nominal input voltage|cmdb\_ci\_ups|nom\_input\_volt|SNMP, UPS MIB| |Nominal input frequency|cmdb\_ci\_ups|nom\_input\_freq|SNMP, UPS MIB| |Nominal output voltage|cmdb\_ci\_ups|nom\_output\_volt|SNMP, UPS MIB| |Nominal output frequency|cmdb\_ci\_ups|nom\_output\_freq|SNMP, UPS MIB| |Rated output VA|cmdb\_ci\_ups|rated\_output\_va|SNMP, UPS MIB| |Rated output power|cmdb\_ci\_ups|rated\_output\_power|SNMP, UPS MIB| |Low battery threshold minutes|cmdb\_ci\_ups|low\_battery\_threshold\_mins|SNMP, UPS MIB| |Audible alarm status|cmdb\_ci\_ups|audible\_alarm\_status|SNMP, UPS MIB| |Low voltage transfer point|cmdb\_ci\_ups|low\_voltage\_transfer\_point|SNMP, UPS MIB| |High voltage transfer point|cmdb\_ci\_ups|high\_voltage\_transfer\_point|SNMP, UPS MIB| |Input index|cmdb\_ci\_ups\_input|input\_index|SNMP, UPS MIB| |Input frequency \(Hz\)|cmdb\_ci\_ups\_input|input\_freq|SNMP, UPS MIB| |Input voltage \(RMS VAC\)|cmdb\_ci\_ups\_input|input\_volt|SNMP, UPS MIB| |Input current \(RMS AAC\)|cmdb\_ci\_ups\_input|input\_current|SNMP, UPS MIB| |Input power \(Watts\)|cmdb\_ci\_ups\_input|input\_power|SNMP, UPS MIB| |Output index|cmdb\_ci\_ups\_output|output\_index|SNMP, UPS MIB| |Output load \(%\)|cmdb\_ci\_ups\_output|output\_load|SNMP, UPS MIB| |Output voltage \(RMS VAC\)|cmdb\_ci\_ups\_output|output\_volt|SNMP, UPS MIB| |Output current \(RMS AAC\)|cmdb\_ci\_ups\_output|output\_current|SNMP, UPS MIB| |Output power \(Watts\)|cmdb\_ci\_ups\_output|output\_power|SNMP, UPS MIB| |Bypass index|cmdb\_ci\_ups\_bypass|bypass\_index|SNMP, UPS MIB| |Bypass voltage \(RMS VAC\)|cmdb\_ci\_ups\_bypass|bypass\_volt|SNMP, UPS MIB| |Bypass current \(RMS AAC\)|cmdb\_ci\_ups\_bypass|bypass\_current|SNMP, UPS MIB| |Bypass power \(Watts\)|cmdb\_ci\_ups\_bypass|bypass\_power|SNMP, UPS MIB| |Alarm index|cmdb\_ci\_ups\_alarm|alarm\_index|SNMP, UPS MIB| |Alarm type|cmdb\_ci\_ups\_alarm|alarm\_type|SNMP, UPS MIB| |Alarm time|cmdb\_ci\_ups\_alarm|alarm\_time|SNMP, UPS MIB| **Parent Topic:**[Network device discovery](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/it-operations-management/itom-visibility/c_NetworkDevices.md)
| title | Uninterruptible power supply \(UPS\) discovery |
| description | Discovery identifies and classifies information about an uninterruptible power supply \(UPS\). |
| locale | en-US |
| canonical_url | https://www.servicenow.com/docs/r/australia/it-operations-management/itom-visibility/r\_DataCollDiscoUnintPowerSupp.html |
| release | australia |
| product | ITOM Visibility |
| classification | itom-visibility |
| topic_type | reference |
| last_updated | 2026-09-10 |
| reading_time_minutes | 2 |
| breadcrumb | Network device discoveryData collected by ITOM VisibilityITOM Visibility referenceITOM VisibilityIT Operations Management |