Storage discovery examples
Discovery creates configuration items (CIs) and CI relationships for physical and logical storage components. Storage can be attached directly to servers or through fibre channel switched fabric.
Direct attached storage
In this example of direct attached storage (DAS), a SCSI drive with two partitions, /dev/sda1 and /dev/sda2, is attached to a Linux host. The /dev/sda1 partition is bootable and supports the system software. The /dev/sda2 partition contains a logical volume configured as a storage pool and mounted to the Linux root file system by Logical Volume Management (LVM). The storage pool uses only 1.5GB of the partition, leaving 13GB of storage available for additional logical volumes.
[Omitted image "LinuxDASExampleDiagram.png"] Alt text: Direct attached storage DAS example
|
Configuration item |
Description |
Tables |
Key reference and Relationships |
|---|---|---|---|
|
/dev/sda |
SCSI physical storage device |
|
[cmdb_rel_ci]- Provides: /dev/sda
|
|
[cmdb_rel_ci]- Provides: /dev/sda
| |||
|
/dev/sda1 |
Partition 1 on the SCSI storage device |
|
[cmdb_ci_file_system]- Mount point: /boot
|
|
[cmdb_rel_ci]- Provides: /dev/sda
| |||
|
/dev/sda2 |
Partition 2 on the SCSI storage device |
|
[cmdb_ci_storage_pool_member]- Pool: /dev/mapper/lvm-root-333-0
|
|
/dev/mapper/lvm-root-333-0 |
Linux logical volume, mapped with LVM to a physical disk storage partition. |
|
[cmdb_ci_file_system]- Mount point: /
|
|
[cmdb_rel_ci]- Provides: /dev/sda
| |||
|
[cmdb_ci_storage_pool_member]- Pool: /dev/mapper/lvm-root-333-0
|
In this example of a fibre channel storage area network (SAN), two physical storage devices, mpatha and mpathb, are attached to a Linux host through fibre switches. The fibre switches provide failover capabilities. The mpatha drive contains two partitions, mpatha1 and mpatha2. The first partition is mounted directly to /boot on the Linux host. Three logical volumes are mapped to the mpatha2 partition and to the physical device mpathb. The logical volumes are mounted as Ext4 file systems in folders on the Linux root structure. This example shows the CIs that Discovery manages for each component and the mounting points for the logical volumes on the Linux host.
[Omitted image "MultipathFibreSANDiagram.png"] Alt text: Multipath fibre channel storage example
Switched fibre fabric details
Discovery creates CIs for the logical sub-components in NAS and SAN environments, such as fibre channel disks and pool components. Discovery also creates CIs for host bus adapters (HBA) and physical block storage. In multipath environments, Discovery creates CI relationships within the switched fibre fabrics that connects the Linux host to the physical storage devices. In this diagram, the fibre fabrics have redundant paths that the SAN environment can use for failover if connections fail.
[Omitted image "MultipathFibreFabricDiagram.png"] Alt text: Fibre fabric redundant paths
Parent Topic:Storage discovery
--- title: Storage discovery examples description: Discovery creates configuration items \(CIs\) and CI relationships for physical and logical storage components. Storage can be attached directly to servers or through fibre channel switched fabric. locale: en-US canonical_url: https://www.servicenow.com/docs/r/australia/it-operations-management/itom-visibility/storage-discovery-examples.html release: australia product: ITOM Visibility classification: itom-visibility topic_type: reference last_updated: "2026-09-10" reading_time_minutes: 2 breadcrumb: [Storage discovery, Data collected by ITOM Visibility, ITOM Visibility reference, ITOM Visibility, IT Operations Management] --- # Storage discovery examples Discovery creates configuration items \(CIs\) and CI relationships for physical and logical storage components. Storage can be attached directly to servers or through fibre channel switched fabric. ## Direct attached storage In this example of direct attached storage \(DAS\), a SCSI drive with two partitions, `/dev/sda1` and `/dev/sda2`, is attached to a Linux host. The `/dev/sda1` partition is bootable and supports the system software. The `/dev/sda2` partition contains a logical volume configured as a storage pool and mounted to the Linux root file system by Logical Volume Management \(LVM\). The storage pool uses only 1.5GB of the partition, leaving 13GB of storage available for additional logical volumes. \[Omitted image "LinuxDASExampleDiagram.png"\] Alt text: Direct attached storage DAS example <table id="table_t5y_fgq_mz"><thead><tr><th> Configuration item </th><th> Description </th><th> Tables </th><th> Key reference and Relationships </th></tr></thead><tbody><tr><td rowspan="2"> /dev/sda </td><td rowspan="2"> SCSI physical storage device </td><td rowspan="2"> - \[cmdb\_ci\_disk\] - \[cmdb\_ci\_storage\_device\] - \[cmdb\_rel\_ci\] </td><td> \[cmdb\_rel\_ci\]- **Provides**: /dev/sda - **Provided by:**/dev/sda1 </td></tr><tr><td> \[cmdb\_rel\_ci\]- **Provides**: /dev/sda - **Provided by:**/dev/mapper/lvm-root-333-0 </td></tr><tr><td rowspan="2"> /dev/sda1 </td><td rowspan="2"> Partition 1 on the SCSI storage device </td><td rowspan="2"> - \[cmdb\_ci\_partition\] - \[cmdb\_ci\_storage\_volume\] - \[cmdb\_ci\_file\_system\] - \[cmdb\_rel\_ci\] </td><td> \[cmdb\_ci\_file\_system\]- **Mount point**: /boot - **File system**: Ext4 </td></tr><tr><td> \[cmdb\_rel\_ci\]- **Provides**: /dev/sda - **Provided by:**/dev/sda1 </td></tr><tr><td> /dev/sda2 </td><td> Partition 2 on the SCSI storage device </td><td> - \[cmdb\_ci\_partition\] - \[cmdb\_ci\_storage\_pool\_member\] </td><td> \[cmdb\_ci\_storage\_pool\_member\]- **Pool**: /dev/mapper/lvm-root-333-0 - **Storage**: /dev/sda2 </td></tr><tr><td rowspan="3"> /dev/mapper/lvm-root-333-0 </td><td rowspan="3"> Linux logical volume, mapped with LVM to a physical disk storage partition. </td><td rowspan="3"> - \[cmdb\_ci\_storage\_device\] - \[cmdb\_ci\_storage\_volume\] - \[cmdb\_ci\_file\_system\] - \[cmdb\_ci\_storage\_pool\] - \[cmdb\_ci\_storage\_pool\_member\] - \[cmdb\_ci\_lvm\_pool\] - \[cmdb\_ci\_lvm\_pool\_member\]\[cmdb\_rel\_ci\] </td><td> \[cmdb\_ci\_file\_system\]- **Mount point**: / - **File system**: Ext4 </td></tr><tr><td> \[cmdb\_rel\_ci\]- **Provides**: /dev/sda - **Provided by:**/dev/mapper/lvm-root-333-0 </td></tr><tr><td> \[cmdb\_ci\_storage\_pool\_member\]- **Pool**: /dev/mapper/lvm-root-333-0 - **Storage**: /dev/sda2 </td></tr></tbody> </table>## Multipath fibre channel storage In this example of a fibre channel storage area network \(SAN\), two physical storage devices, `mpatha` and `mpathb`, are attached to a Linux host through fibre switches. The fibre switches provide failover capabilities. The `mpatha` drive contains two partitions, `mpatha1` and `mpatha2`. The first partition is mounted directly to `/boot` on the Linux host. Three logical volumes are mapped to the `mpatha2` partition and to the physical device `mpathb`. The logical volumes are mounted as Ext4 file systems in folders on the Linux root structure. This example shows the CIs that Discovery manages for each component and the mounting points for the logical volumes on the Linux host. \[Omitted image "MultipathFibreSANDiagram.png"\] Alt text: Multipath fibre channel storage example ## Switched fibre fabric details Discovery creates CIs for the logical sub-components in NAS and SAN environments, such as fibre channel disks and pool components. Discovery also creates CIs for host bus adapters \(HBA\) and physical block storage. In multipath environments, Discovery creates CI relationships within the switched fibre fabrics that connects the Linux host to the physical storage devices. In this diagram, the fibre fabrics have redundant paths that the SAN environment can use for failover if connections fail. \[Omitted image "MultipathFibreFabricDiagram.png"\] Alt text: Fibre fabric redundant paths **Parent Topic:**[Storage discovery](https://raw.githubusercontent.com/ServiceNow/ServiceNowDocs/australia/markdown/australia/it-operations-management/itom-visibility/c_Storage.md)
| title | Storage discovery examples |
| description | Discovery creates configuration items \(CIs\) and CI relationships for physical and logical storage components. Storage can be attached directly to servers or through fibre channel switched fabric. |
| locale | en-US |
| canonical_url | https://www.servicenow.com/docs/r/australia/it-operations-management/itom-visibility/storage-discovery-examples.html |
| release | australia |
| product | ITOM Visibility |
| classification | itom-visibility |
| topic_type | reference |
| last_updated | 2026-09-10 |
| reading_time_minutes | 2 |
| breadcrumb | Storage discoveryData collected by ITOM VisibilityITOM Visibility referenceITOM VisibilityIT Operations Management |