Connect to the Claroty CTD

task australia Updated Sep 10, 2026 1 min read connect-to-claroty-ctd-vr-integration.md
Raw file servicenow.com

Connect to the Claroty CTD to begin the Vulnerability Integration setup.

Before you begin

Before performing the setup, change the application scope to Vulnerability Response Integration with Claroty CTD by selecting the globe icon ([Omitted image "icon-scope.png"] Alt text: Globe icon) in the navigation bar.

Role required: admin

Procedure

  1. Navigate to All > Claroty CTD Vulnerability Integration > Admin > Setup.

  2. In the Connect to Claroty CTD section, select the Setup Connections task.

  3. On the Setup Connections task page, select Configure.

    The Claroty CTD Connection Manager page opens.

  4. On the form, fill in the following fields.

Field

Description

Claroty EMC URL

URL of the Claroty CTD Enterprise Management Console (EMC).

Minimum CVSS Score

This field is visible if you select 5.0.x or 5.1.x as the CTD version.

If applicable, you can filter which vulnerabilities are imported based on their Common Vulnerability Scoring System (CVSS) score. The filter is actually values that ranges from 0.0 to 10.0 and acts as a greater than or equal filter.

For example, if you enter the score value as 9 the integration imports vulnerabilities with a CVSS score of 9.0-10.0.

EPSS Score (Optional)

This field is visible if you select 5.1.x or later as the CTD version.

If applicable, you can filter which vulnerabilities are imported based on their Exploit Prediction Scoring System (EPSS) score. The EPSS Score uses the following values that acts as a filter: Critical, High, Medium, and Low.

You can select only one option. For example, if you select Critical as the EPSS Score value, Claroty CTD only imports the vulnerabilities with a Critical EPSS score.

User Name

Claroty account user name.

Password

Claroty account password.

MID Server

If your Claroty EMC is on-premises, a MID Server may be required. If so, select a MID Server here.

5. Select **Update**.
  1. Select Test Connection.

    If the connection test is successful, a Results 200 output message appears. An unsuccessful connection attempt displays the error code and the message received from Claroty.

Parent Topic:Configure the Vulnerability Response Integration with Claroty CTD

Search documentation
Search document titles and file paths on the australia branch